Specifications
Voltage DC
Range:0 - 600.0 V
Accuracy:1% ± 5 counts
Voltage AC
Fluke 333/334 
Range:0 - 600.0 V
Accuracy:1% ± 5 counts (50/60 Hz)
AC Response:Averaging
Fluke 335 
  
Range:0 - 600.0 V
Accuracy:1% ± 5 counts (50/60 Hz)
AC Response:True-rms
  
Fluke 336/337 
Range:0 - 600.0 V
Accuracy:1% ± 5 counts (20-100 Hz), 6% ± 5 counts (100-400 Hz)
AC Response:True-rms
Current DC
Fluke 336 
Range:0 - 600.0 A
Accuracy:2% ± 5 counts
  
Fluke 337 
Range:0 - 999.9 A
Accuracy:2% ± 5 counts
Current AC
Fluke 333 
Range:0 - 400.0 A
Accuracy:2% ± 5 counts (50/60 Hz)
AC Response:Averaging
  
Fluke 334 
Range:0 - 600.0 A
Accuracy:2% ± 5 counts (50/60 Hz)
AC ResponseAveraging
  
Fluke 335 
Range:0 - 600.0 A
Accuracy:2% ± 5 counts (50/60 Hz)
Crest Factor(50/60 Hz):2.4 @ 500A, 2.0 @ 600A, add 2% for CF>2
AC Response:True-rms
  
Fluke 336 
Range:0 - 600.0 A
Accuracy:2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz)
Crest Factor(50/60 Hz):3 @ 500A, 2.5 @ 600A, add 2% for CF>2
AC Response:True-rms
  
Fluke 337 
Range:0 - 999.9 A
Accuracy:2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz)
Crest Factor(50/60 Hz):3 @ 500A, 2.5 @ 600A, 1.42@1000 A, add 2% for CF>2
AC Response:True-rms
Resistance
Fluke 333 
Range:0 - 600.0 ?
Accuracy:1.5% ± 5 counts
  
Fluke 334/335/336/337 
Range:0 - 600.0 ?, 600 - 6000 ?
Accuracy:1.5% ± 5 counts
Frequency
Fluke 337 
Range:5 - 400Hz
Accuracy:0.5% ± 5 counts
Trigger Level:10-100 Hz >= 5A, 5-10 Hz, 100-400 Hz >=10A
Inrush Current
Fluke 334/335/336/337 
Integration Time:100 ms
Continuity
 <= 30 ?
MIN/MAX
 Fluke 337 only

Environmental Specifications
Operating Temperature
 -10 °C to +50 °C, -14 °F to 122 °F
Storage Temperature
 -40ºC to +60ºC, -22 °F to 140 °F
Operating Altitude
 2,500 meters max, 6,500 ft max
Temperature De-rating
 Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC (above 82.4°F or below 64.4°F)

Safety Specifications
Safety Rating
 IEC 1010-2-032, 600V CAT III

Mechanical & General Specifications
Size
Fluke 333/334/335 
 240mm x 80mm x 40mm (9.375" x 3.125" x 1.625")
 -
Fluke 336/337 
 250mm x 80mm x 40mm (9.875" x 3.125" x 1.625")
Weight
 310 g (11oz)
Warranty
 Three years
Battery Life
 Alkaline approximately 150 hours continuous
 Automatic low battery indicator
Backlight
 Fluke 334/335/336/337
Display Hold
 Yes